Standards Policies and Guidelines
Are you building a new development? Make sure to review the engineering and landscaping requirements in Caledon. These requirements ensure that all developments have a similar design and construction throughout the Town.
Developers and contractors must review and meet the guidelines set out by the Town. These development standards, policies and guidelines provide:
- Engineering submission requirements
- Drawing submission requirements
- Drawing specifications
- Landscape and urban design requirements
- Design requirements for storm sewers, roadways, grading, lighting, noise, and erosion and sediment control
- Administration fees and requirements
- Inspection requirements
Development Standards Manual |
If an alternate format is required please contact 311. |
Consolidated Linear Infrastructure Environmental Compliance Approval (CLI-ECA) | |||||||||||||||||||||||||||||
Town of Caledon Environmental Compliance Approval Conditions ECA No. 324-S701 Appendix A Performance Criteria Design Criteria for Environmental Compliance Approval
|
|||||||||||||||||||||||||||||
100 Engineering General | |||||||||||||||||||||||||||||
STD DWG 100 - Typical Title Pages STD DWG 101 - General Notes Storm Sewers STD DWG 102 - General Notes Roadworks STD DWG 103 - Rainfall Intensity Curves STD DWG 104 - Storm Design Sheet STD DWG 105 - Standard Plan & Profile STD DWG 106 - First Submission Minimum Requirements |
|||||||||||||||||||||||||||||
200 Roads | |||||||||||||||||||||||||||||
STD DWG 200 - 8.0m Laneway (5.4m Pavement) STD DWG 201 - 16.0m Local Window Street (7.9m Pavement) STD DWG 202 - 18.0m Local Road (7.9m Pavement) STD DWG 203 - 20.0m Local Urban_Rural (8.7m Pavement) STD DWG 204 - 20.0m Neighbourhood Collector (8.9m Pavement) STD DWG 205 - 22m Local Through_Urban (9.8m Pavement) STD DWG 206 - 22.5m Local Industrial Rd (10.4m Pavement) STD DWG 207 - 24.0m Urban_Local Divided Rd (9.8m Pavement) STD DWG 208 - 24.0m Local Industrial Rd (11.0m Pavement) STD DWG 209 - 26.0m Local Industrial Rd (9.8m Pavement) STD DWG 210 - 26.0m Urban_Collector Full_Part Service (9.8m) STD DWG 211 - 26.0m Industrial Collector (13.9m Pavement) STD DWG 212 - 30.0m Arterial Rd (7.0m-15.0m Pavement) STD DWG 213 - 30m Urban_Collector 4 Lanes (15m Pavement) STD DWG 214 - Local Residential Road Elbow Design STD DWG 215 - Industrial Cul-de-sac STD DWG 216 - Residential Cul-de-sac STD DWG 217 - Temporary Cul-de-sac STD DWG 218 - Typical 100mm Subdrain Detail STD DWG 219 - Joint Use Utility Corridor STD DWG 220 - 3.0m Multi-Use Recreational Pathway STD DWG 221 - Impressed Concrete Splash Pad STD DWG 222 - Standard Condo Road Section |
|||||||||||||||||||||||||||||
300 Grading | |||||||||||||||||||||||||||||
STD DWG 300 - Minimum Requirements for Lot Grading Plans STD DWG 301 - Lot Grading & Drainage STD DWG 302 - Catch Basin Sediment Trap |
|||||||||||||||||||||||||||||
400 Traffic Control | |||||||||||||||||||||||||||||
STD DWG 400 - Standard Street Name & RegulatorySGN |
|||||||||||||||||||||||||||||
500 Storm Sewer | |||||||||||||||||||||||||||||
STD DWG 500 - STM Sewer Service Conn for Flexible Pipe STD DWG 501 - Storm Sewer Service Connection for Rigid Pipe |
|||||||||||||||||||||||||||||
600 Fencing, Bollards and Gates Design Standards |
|||||||||||||||||||||||||||||
STD DWG 600 - Chain Link Fence
STD DWG 601 - Chain Link Fence Single Gate Detail STD DWG 602 - Chain Link Fence Double Gate Detail STD DWG 603 - Page Wire Fencing Detail STD DWG 604 - Post and Rail Fence Detail STD DWG 605 - Wood Screen Fence Detail STD DWG 606 - Tree Preservation Fencing STD DWG 607 - Emergency Maintenance Access Road Gate STD DWG 609 - Walkway P-Gate With Support Bracing STD DWG 610 - Swing Bollard Access STD DWG 612 - Removable Bollard STD DWG 613 - Noise Attenuation Barrier and Berm STD DWG 614 - Acoustic Fence Detail STD DWG 615 - Acoustic Fence Detail STD DWG 616 - Acoustic Fence Detail STD DWG 617 - Acoustic Fence Detail STD DWG 618 - Trailway Entry Gate |
Fencing standards
The Town's fencing standards provide requirements for all chain link fences and trail and walkway gates. This includes the size, location, height, and material for different types of fences.
Grading standards
Caledon's grading standards provide developers and contractors with requirements for land grading and draining for all new and existing developments.
Landscaping standards
Caledon's landscaping standards provide requirements for planting trees and shrubs in Town.
Outdoor lighting standards
The Town's outdoor lighting standards provide standards and specifications for cobra light coach LED lighting fixtures, streetlight poles and photocell censors. Developers, consultants and contractors working on new or existing streetlights in Town must follow these standards.
Road standards
The Town's road standards provide detailed drawings for roads and sidewalks in Caledon. They provide regulations for when sidewalks and curbs are necessary as well as measurement requirements for roads and sidewalk plans.
Storm sewer standards
The Town's storm sewer standards provide standard requirements for the diameter, depth and location of all storm sewers for new and existing developments.
Traffic control standards
Caledon's traffic control standards provide requirements for all traffic and street signs. This includes the size, material and position of all traffic signs.
Contact us for the various requirements, specifications and documents mentioned above.